Drypower 12SB7.2P-F2 12V 7.2Ah Sealed Lead Acid Battery for Home Alarms and NBN

12SB7.2P-F2
Drypower 12SB7.2P-F2 12V 7.2Ah Sealed Lead Acid Battery for Home Alarms and NBN

$29 inc GST.

Our Best Price

Qty:     

Shipping & Handling Calculator:

Post Code:
Model No 12SB7.2P-F2
Selling Unit EACH
Description Drypower 12SB7.2P-F2 12V 7.2Ah Sealed Lead Acid Battery for Home Alarms and NBN
Application Backup and Main Power Cyclic Use
Chemistry Sealed Lead Acid (SLA)
Voltage 12V
Nominal Capacity 7200mAh
Brand Drypower
Termination F2 (6.35mm Spade)
Width 151mm
Height 94mm
Length/Breadth/Depth 65mm
Weight 2400g
Weight(kg) 2.450
Brand Drypower

Drypower 12V 7.2Ah Sealed Lead Acid Battery for Backup, Standby and Cyclic Use etc House Alarms, NBN.

Replaces BP7.5-12, BP8-12, EP7-12, EVP7-12, PS1270L, GP1272, GPL1272, EVX1272, DM12-7.2, DM12-7.5, CF-12V7.2, HGL7.2-12, FG20722, DC7-12, CB12V7.5AH, CBC12V8.0AH, NP7-12, LP12-6.5, LP12-7.0, LP12-7.2, LP12-7.5, LP12-7.8, LP12-8.5, LPC12-7.2, LPC12-8.0, LPS12-7.5, WP7.2-12, LC-R127R2P1, PDC-1275, PE12V7.2, RM12-7.2DC, RT1272, RT1275, RT1280, RT1290, CP1270

Multipurpose VRLA AGM batteries for superior service life and dependable performance.

Designed for constant/float backup and light cycle use in security alarm panels, emergency lighting, toys, test equipment, general electrics, automatic doors, marine power and more.

Backup & Main Power Series

  • Industry leading 99.99% pure lead content for superior service life and dependable performance.
  • Thicker plate design & higher percentage of tin content compared with the industry standard to maximise battery standby life by minimising sulphation.
  • Suitable for use in any orientation (except inverted) for use in hard to reach or remote locations.
  • Maintenance free and non-spillable design for long service life.
  • 6V and 12V models available for consumer and industrial needs, from children's ride on toys to medical monitoring equipment and more.

Suitable for:

  • General Purpose
  • Backup Power
  • Medical Equipment
  • Alarm Panels
  • Weigh Machines & Equipment

 

STEP BY STEP PROCEDURE TO CHANGE YOUR HOME ALARM BATTERIES

The majority of home alarm batteries are 12 Volt 7 Amp Hour the batteries are 150mm long 65mm wide and 95mm high, available from Batteries Direct the batteries will always be the same dimensions however the Amp Hour rating of the battery may vary between brands this does not affect the performance of the alarm.

It is a simple procedure to change the battery and can save you many $$$

When the Battery light shows it is time to replace the battery this is usually evey 3-5 years

The usual procedure to change the battery is:

1. Open the panel (the battery is usually located inside)

2. The Tamper alarm will sound

3. Enter your Pin Number this will turn the alarm off

4. Check the battery Part Number, Size, Voltage and Amp Hour rating of the battery

5. Close the Panel Re-Enter your Pin Number to set the Alarm, then in some cases again to put the alarm on standby

When you have purchased your 12 Volt 7 Amp Hour battery repeat 1-3

6. Take care not to pull on the wires when removing the battery connectors and make sure you replace them on the corresponding terminal of the new battery

The repeat step 5

CONGATULATIONS YOU HAVE JUST SAVE YOURSELF $50 TO $100.00

NBN Battery Replacement

With the on-going NBN (National Broadband Network) roll out spreading across Australia, the replacement battery market will certainly follow suit.

Customers who opt for the Battery Backup service for their power supply are supplied with a 12V 7.2Ah battery as part of the package. When this battery requires replacing, they are encouraged to download the following document, and told to take it to a battery retailer.

Form here - http://www.nbnco.com.au/content/dam/nbnco/documents/NBN-power-supply-battery-backup-battery-specification.pdf

The specifications released are outlined below:
Battery Type:   12V 7.0-7.2Ah 6cell VRLA Sealed Lead Acid Battery
Dimensions:    150mm (W) x 94mm (H) x 64mm (D)
Terminals:       Quick Disconnect F2 - 6.35mm(W) x 0.81mm(T) Faston Tab terminals
                     These are to be located 8mm from the side edge of the battery casing and 12-24mm from the top edge of the battery casing. Only batteries that have terminals in these exact locations will function.

Batteries such as the Drypower 12SB7.2P-F2 which meets the above specifications to a tee! 

Optional equivalents available from our website
Product Terminal      
Application    
Century PS1270L F2
Stand By
Century PS1270S F1
Stand By
Drypower 12SB7.2P-F1 F1
Multi Use
Drypower 12SB7.2P-F2 F2
Multi Use
Drypower 12SB7P-F1 F1 Stand By
Fullriver DC7-12 F2
Cyclic
Fusion CB12V7.5AH F1
Stand By
Fusion CBC12V8.0AH F2
Cyclic
Fusion V-LFP-12-7.5 F2
Stand By
Panasonic LC-R127R2P F1
Multi Use
Panasonic LC-R127R2P1 F2
Multi Use
Panasonic UP-VW1236P1 F2
Stand By
Panasonic UP-VW1245P1 F2
Stand By
Remco RM12.7.2DC F1
Cyclic
Remco RM12-7.2 F1
Stand By
TAICO TP1270 F1
Multi Use

Terminal
F1 - 4.75mm Spade Terminals
F2 - 6.35mm Spade Terminals

Application
Cyclic - Deep cycle applications
Stand By - Stand by applications use for USP, home alarm etc
Multi Use - Can be use for both Deep cycle and Stand by applications

Drypower Battery Termination Guide 12SB7.2P-F21401943613_1.pdf 